Features
- Ethernet uploading and downloading capability for Internet and Intranet use via 7845i or
7845i-ENT
- Supports four graphic touchscreen keypads
- Wireless keys can be programmed without using zones
- Eight on-board hardwired zones standard (15 when Zone Doublingfeature is used)
– 40 hardwired expansion zones
– 40 wireless expansion zones
- Two low current on-board trigger outputs
- 100 Event Log viewable at system keypads with time/date stamp
- 48 system user codes assignable to either partition
- Expandable to 48 total zones when used with hardwired and/or wirelessexpansion
modules
- Two independent partitions plus a common partition – Global Arming from any system
keypad
– Goto function to view or operate one partition from the other
– Separate partition account numbers
- 16 output devices
– Relays (Model 4204 RelayModules, or 4229 ExpansionModule), and/or
– X-10®devices (when used with a 4300 Transformer)
- Four installer configurable zone types allows the installer to create custom zone types
by assigning all zone attributes
- Supports four-wire, and up to 16 two-wire smokes
– Works with Sentrol CleanMe™maintenance signal
- Multiple actions on output devicesdepending on system “state”
– Turns lights off when system arms
– Turns the same light on when system disarms
– Flashes same lights when system is in alarm condition
- Built-in phone line cut monitor with programmable delay and annunciation options
– Display on system keypads
– Trigger local sounders
– Trigger system bell
Security Dealer Features
- Automatic System Load Shed
– During extended AC power fail, the system battery will be disconnected to prevent
irreversible battery failure. Reduces service calls to replace batteries.
Dynamic Signaling
– Reduces redundant reporting to the central station when multiple reporting methods
are used; i.e. digital dialer and AlarmNet radio
The VISTA-20PUL complies to the following listings (listed at UL as VISTA 20P & UL-KT):
- US Standards: UL LISTINGS
- UL 985 - Household Fire Warning System Units
- UL 1023 - Household Burglar-Alarm System Units
- UL 609 - Local Burglar Alarm Units and Systems
- UL 365 - Police Station Connected Burglar Alarm Units and Systems
- UL 1610 - Central Station burglar Alarm Units
- UL 1635 - Digital Alarm Communicator System Units
Canadian Standards: CUL LISTINGS
- CAN/ULC-S303-M91-STANDARD for Local Burglar Alarm Units and Systems.
- ULC Subject C1023-Standard for Household Burglar Alarm System Units.
- CAN/ULC-S545-M89-Standard for Residential Fire Warning System Control Units.
- CAN/ULC-S304-M88-Standard for Central and Monitoring Station Burglar Alarm Units.
- Canadian Electrical Code, Part I.
VISTA-20PUL Spec Sheet